Archeops 1999 Trapani Flight detector configuration Optical configuration of bolometers on the sky (from Jacques' load_archeops_ins.pro) fnumber of shaul hanany : fnumber=1.75 55mm ---> 1.5 degrees on the sky thus the focal length is : foc = 55mm/1.5degrees = 0.055/1.5 * 180/pi = 2.101 meters equivalent telescope diameter = Dtel = foc/fnumber = 1.200 meters bolometers are integrated with a separation of 28.6 mm on the focal plane this corresponds to 0.78 degrees on the sky, or 46.8 minutes config on the sky: /\ o O elevation || positive scanning, clockwise || . O o ----------> || || x O /\ 4 2 elevation || positive scanning, clockwise || 6 1 5 ----------> || || x 3 x = no detector . = 353 GHz channel 3 o = 217 GHz channel 2 O = 143 GHz channel 1 Numbering in Fits TOI (eop is electrical output plug) (from Gispert et al note #1 and logbooks) new boloMuV11 old bolotens_6 channel1-bolo1 on eop12 new boloMuV8 old bolotens_4 channel1-bolo2 on eop9 new boloMuV13 old bolotens_8 channel1-bolo3 on eop14 new boloMuV9 old bolotens_5 channel1-bolo4 on eop10 new boloMuV4 old bolotens_2 channel1-bolo5 on eop5 new boloMuV15 old bolotens_10 channel1-bolo6 on eop16 Configuration of thermometers on the focal plane (from Alain Benoit and Bruno Maffei logbooks) new boloMuV2 old bolotens_1 is Thermo-Dum100mK2 on eop3 dilution new boloMuV1 old bolotens_0 is Thermo-Dum100mK4 on eop2 pied1 (regulation) new boloMuV6 old bolotens_3 is Thermo-Dum100mK6 on eop7 on bolo4 (Pb?) new boloMuV14 old bolotens_9 is Thermo-Lou100mK2 on eop15 on bolo5 new boloMuV12 old bolotens_7 is Thermo-Lou100mK3 on eop13 plate with bolometers new boloMuV16 old bolotens_11 is Thermo-Lou1.6K5 on eop17 1.6K stage new boloMuV17 old bolotens_12 is Thermo-Lou1.6K6 on eop18 1.6K stage new boloMuV18 old bolotens_13 is Thermo-Lou10K7 on eop19 10K stage Alain Benoit and F.-Xavier Desert, 1999/08/18